Overview

Most cells that die after a thaw were lost in the first ten minutes. This protocol covers receipt, storage, thawing, and plating of cryopreserved cell lines from Kulture Scientific, and it keeps those first minutes short and predictable: a fast thaw, a gentle dilution and spin to remove the cryoprotectant, and a conditioned vessel that is ready before the vial leaves storage.

Purpose and Scope

This protocol applies to all cryopreserved cell lines from Kulture Scientific unless the cell line datasheet gives different instructions. The datasheet lists the recommended medium, the culture vessel, and whether the line needs a coated surface. Where the datasheet and this protocol differ, follow the datasheet.

ⓘ Lines that need a coated surface are coated before thawing. See the Subculture Protocol for Adherent Cell Lines on Coated Vessels, Step 1.

Precautions

Culture hazards

Maintain strict aseptic technique. The vial exterior is not sterile after the water bath.
Thaw quickly and remove the DMSO right away. DMSO is toxic to some cell lines, especially at room temperature and above, and slow thawing allows damaging ice recrystallization.
Do not refreeze a thawed vial.

Personnel hazards

Liquid nitrogen causes severe cold burns on contact. Wear insulated cryogenic gloves, a lab coat, and a face shield when removing vials from storage.
Vials stored submerged in liquid nitrogen can take in liquid through a poor seal and burst as they warm. Thaw behind a face shield or in a closed container.
Human-derived cell lines must be handled at BSL-2 unless the datasheet states otherwise.

Materials Needed

Biosafety cabinet (Class II)
CO₂ incubator (37°C, 5% CO₂, humidified)
37°C water bath
Inverted light microscope
Centrifuge
Hemocytometer or automated cell counter
70% ethanol
0.4% Trypan blue or equivalent viability stain (optional)
Sterile 15 mL or 50 mL conical tubes
PPE: insulated cryogenic gloves, face shield, lab coat, nitrile gloves
Pipettor and sterile pipette tips KS
T25 flask or the vessel listed on the datasheet
Cell culture media, as listed on the cell line datasheet KS
Kulture Coating Solution (KM-UCS-1), if the datasheet calls for coating KS

On Receipt

ItemRequirement
Shipping conditionFrozen vials on dry ice
Long-term storageVapor phase of liquid nitrogen, below −130°C
Short-term storage−80°C for up to 1 week (not recommended)
Do notLet vials thaw before use, or store them at −20°C
ⓘ Move vials to liquid nitrogen or −80°C as soon as the package arrives. Every temperature swing costs post-thaw viability.

Thawing and Plating

1

Check the datasheet

Confirm the recommended medium, the culture vessel, and whether the line needs a coated surface.

2

Prepare the vessel

If coating is required, coat and rinse the vessel first so it is ready when the cells are. Otherwise, use a standard tissue culture-treated vessel.

◆ Coating takes at least 60 minutes. Start it before you pull the vial from storage.
3

Condition the medium

Add complete growth medium to the vessel (for example, 5 mL to a T25, or the volume on the datasheet) and place it in the incubator for 15 to 30 minutes. The medium reaches 37°C and its pH equilibrates with the CO₂ atmosphere before the cells go in.

4

Prepare the dilution tube

Add 9 mL of pre-warmed complete growth medium to a sterile 15 mL or 50 mL conical tube.

◆ We prefer a 50 mL tube. The wider opening makes it easier to add cells dropwise and to aspirate cleanly above the pellet.
5

Thaw the vial

Swirl the vial in a 37°C water bath until only a small ice crystal remains, usually 1 to 2 minutes. Keep the cap above the water line.

⚠ Do not leave the vial in the water bath after the ice is gone. Warm DMSO damages cells quickly.
6

Disinfect

Wipe the vial with 70% ethanol and move it into the biosafety cabinet.

7

Dilute dropwise

Transfer the vial contents dropwise into the 9 mL of medium in the conical tube. Adding the cells slowly limits osmotic shock as the DMSO is diluted.

8

Let the cells equilibrate

Let the tube stand for no more than 5 minutes before centrifuging. DMSO takes a few minutes to diffuse out of the cells, and letting it leave gradually at this dilution reduces osmotic stress before the cells are pelleted and moved into fresh medium.

9

Centrifuge

Centrifuge at 300 × g for 5 minutes at room temperature. If the pellet is loose, small, or cells remain in the supernatant, increase gradually, up to 800 × g. Use the lowest speed that gives a firm pellet, especially for primary or sensitive cells. Aspirate the supernatant without disturbing the pellet.

ⓘ DMSO is toxic to some cell lines, so this protocol removes it before plating. Some robust lines can be plated directly into medium without a spin, but that call comes with experience with the line. When in doubt, spin.
10

Count (optional)

If you want a viability count, gently resuspend the pellet in 1 to 2 mL of the conditioned medium and take your sample now, after the DMSO is out.

⚠ Never run a trypan blue count on cells that still contain DMSO. DMSO makes membranes leaky, so live cells take up the dye and read as dead, giving a falsely low viability.
11

Plate the cells

Gently resuspend the pellet in 1 to 2 mL of the conditioned medium (if you have not already) and transfer it to the conditioned vessel. Move the vessel up and down, then side to side, several times to distribute the cells.

⚠ Do not swirl. Swirling pushes cells to the center of the vessel and gives uneven growth.
12

Incubate and maintain

Place the vessel in the incubator at 37°C, 5% CO₂. Change medium as directed on the datasheet, typically every 2 to 3 days, until the culture is ready to subculture. See the Visual Guide to Confluency for when to passage.

Troubleshooting

IssueLikely CauseCorrective Action
Low viability after thawSlow thaw, delay before dilution, temperature swings in storage, or counting before the DMSO was removedThaw quickly, dilute and spin out the DMSO right away, and check the vial's storage history
Few cells attached at 24 hoursWrong vessel, coating required but not used, or cells swirled to the centerCheck the datasheet for coating requirements; distribute up and down, then side to side
Medium turns yellow quicklyHigh cell density or contaminationCheck under the microscope for contamination, then change the medium
Vial partially thawed on arrivalDry ice ran out in transitDo not use. Contact us for a replacement.

Frequently Asked Questions

Slow warming lets small ice crystals regrow into larger ones that rupture membranes. A fast thaw gets cells through that window quickly. Once thawed, the cells are sitting in concentrated DMSO, so plate them right away.
DMSO is toxic to some cell lines, and removing it before plating keeps exposure as short as possible. Some robust lines tolerate DMSO and can be plated directly without a spin. Knowing which lines can skip the spin comes with experience; when in doubt, spin.
Only after the DMSO has been removed. DMSO left in the cells makes membranes leaky, so live cells take up trypan blue and count as dead. Count from the resuspended pellet, not from the vial or the dilution tube.
Medium warmed on the bench is at 37°C but its pH is off until it equilibrates with the CO₂ in the incubator. Conditioning the medium in the vessel first means freshly thawed cells land in medium at the right temperature and pH.
Swirling sends cells toward the center of the vessel, where they settle in a dense patch and leave the edges sparse. Moving the vessel up and down, then side to side, spreads them evenly.
Only for up to a week. Viability drops over time at −80°C. For long-term storage, use the vapor phase of liquid nitrogen.