- All products
- PCR
- 384-well PCR Plates, Double and Single Cut Corner
- PCR
Hard-frame 384-well PCR plates with polycarbonate frame and polypropylene wells โ engineered for high-throughput qPCR, thermal cycling, robotic automation, and heat sealing. The two-component hard-frame design combines a dimensionally stable polycarbonate frame with chemically inert polypropylene wells, delivering the thermal resistance and rigidity needed for demanding automation workflows while maintaining the sample compatibility of PP well surfaces.
Available in single cut corner (one orientation notch at A24) for standard ABI instrument compatibility, and double cut corner (two notches at A24 and P24) for broader compatibility with ABI and Lightcycler instruments. Available in clear and white base color with clear or white well color. All variants feature black print alphanumeric markings on the plate frame. 40 ยตL per well. Non-sterile. Certified DNase/RNase-free and endotoxin-free. 10 plates per box, 100 plates per case.
- Hard-frame two-component construction โ polycarbonate frame provides dimensional stability under thermal cycling and heat sealing; polypropylene wells maintain chemical inertness and sample compatibility
- Eliminates warping and distortion โ PC frame resists the shrinkage and deformation commonly observed in single-component polypropylene plates under high-temperature thermal cycling and heat sealing
- Robotic automation compatible โ rigid PC frame provides consistent dimensional geometry for reliable robotic gripper handling and plate positioning in automated liquid handling systems
- Single cut corner (A24) โ one orientation notch prevents incorrect plate loading in ABI and standard 384-well compatible instruments
- Double cut corner (A24 and P24) โ two orientation notches for broader compatibility with ABI and Lightcycler instruments โ preferred for multi-platform labs
- Clear base option โ transparent PC frame for instrument plate detection and fluorescence bottom-reading applications
- White base option โ white PC frame enhances fluorescence signal reflection for improved detection sensitivity
- Clear wells โ transparent PP wells for standard SYBR Green and probe-based qPCR detection
- White wells โ white PP well surface reflects emitted fluorescence toward the detector for improved sensitivity in low-template applications
- Ultra-thin PP well walls โ optimal and uniform heat transfer across all 384 wells for consistent thermal cycling performance
- Raised well rims โ secure sealing with pressure-sensitive films, adhesive seals, and heat-sealing technologies
- Black print alphanumeric markings โ all variants feature black printed plate markings for clear well identification
- DNase/RNase-free and endotoxin-free โ certified for sensitive nucleic acid and high-throughput screening applications
| Specification | Detail |
|---|---|
| Frame Material | Polycarbonate (PC) |
| Well Material | Polypropylene (PP) |
| Well Count | 384 wells โ 16 rows ร 24 columns |
| Well Volume | 40 ยตL per well |
| Cut Corner Options | Single cut corner (A24) ย |ย Double cut corner (A24 and P24) |
| Single Cut Corner Compatibility | โ ABI and standard 384-well instruments |
| Double Cut Corner Compatibility | โ ABI and Lightcycler instruments |
| Base Color Options | Clear ย |ย White |
| Well Color Options | Clear ย |ย White |
| Plate Labeling | Black print โ all variants |
| Sealing Compatibility | Pressure-sensitive films ย |ย Adhesive seals ย |ย Heat-sealing |
| Footprint | Standard SBS/ANSI 384-well format |
| Sterile | โ ๏ธ Non-Sterile |
| DNase / RNase-free | โ Certified |
| Endotoxin-free | โ Certified |
| Packaging | 10 plates per box ย |ย 100 plates per case |
- Store in original packaging in a clean, dry environment away from direct sunlight and UV exposure
- Maintain storage temperature between 15ยฐC and 30ยฐC prior to use
- Handle plates by the edges โ avoid contaminating well surfaces with skin oils and nucleases
- Use powder-free gloves when handling plates for sensitive nucleic acid applications
- Verify cut corner orientation matches your instrument's plate loading requirements before use
- Use a 384-well compatible multichannel pipette or automated liquid handler for sample loading โ manual pipetting of 384-well plates is not recommended
- Seal plates immediately after sample loading to prevent evaporation of the small 40 ยตL reaction volumes
- Centrifuge briefly at low speed after sealing to collect sample at the well base and remove air bubbles
- Verify plate sits flat in the thermal cycler block โ the rigid PC frame should ensure consistent plate seating
- Dispose of used plates per your institution's biosafety and waste disposal guidelines
Hard-frame 384-well PCR plates with polycarbonate frame and polypropylene wells โ engineered for high-throughput qPCR, thermal cycling, robotic automation, and heat sealing. The two-component hard-frame design combines a dimensionally stable polycarbonate frame with chemically inert polypropylene wells, delivering the thermal resistance and rigidity needed for demanding automation workflows while maintaining the sample compatibility of PP well surfaces.
Available in single cut corner (one orientation notch at A24) for standard ABI instrument compatibility, and double cut corner (two notches at A24 and P24) for broader compatibility with ABI and Lightcycler instruments. Available in clear and white base color with clear or white well color. All variants feature black print alphanumeric markings on the plate frame. 40 ยตL per well. Non-sterile. Certified DNase/RNase-free and endotoxin-free. 10 plates per box, 100 plates per case.
- Hard-frame two-component construction โ polycarbonate frame provides dimensional stability under thermal cycling and heat sealing; polypropylene wells maintain chemical inertness and sample compatibility
- Eliminates warping and distortion โ PC frame resists the shrinkage and deformation commonly observed in single-component polypropylene plates under high-temperature thermal cycling and heat sealing
- Robotic automation compatible โ rigid PC frame provides consistent dimensional geometry for reliable robotic gripper handling and plate positioning in automated liquid handling systems
- Single cut corner (A24) โ one orientation notch prevents incorrect plate loading in ABI and standard 384-well compatible instruments
- Double cut corner (A24 and P24) โ two orientation notches for broader compatibility with ABI and Lightcycler instruments โ preferred for multi-platform labs
- Clear base option โ transparent PC frame for instrument plate detection and fluorescence bottom-reading applications
- White base option โ white PC frame enhances fluorescence signal reflection for improved detection sensitivity
- Clear wells โ transparent PP wells for standard SYBR Green and probe-based qPCR detection
- White wells โ white PP well surface reflects emitted fluorescence toward the detector for improved sensitivity in low-template applications
- Ultra-thin PP well walls โ optimal and uniform heat transfer across all 384 wells for consistent thermal cycling performance
- Raised well rims โ secure sealing with pressure-sensitive films, adhesive seals, and heat-sealing technologies
- Black print alphanumeric markings โ all variants feature black printed plate markings for clear well identification
- DNase/RNase-free and endotoxin-free โ certified for sensitive nucleic acid and high-throughput screening applications
| Specification | Detail |
|---|---|
| Frame Material | Polycarbonate (PC) |
| Well Material | Polypropylene (PP) |
| Well Count | 384 wells โ 16 rows ร 24 columns |
| Well Volume | 40 ยตL per well |
| Cut Corner Options | Single cut corner (A24) ย |ย Double cut corner (A24 and P24) |
| Single Cut Corner Compatibility | โ ABI and standard 384-well instruments |
| Double Cut Corner Compatibility | โ ABI and Lightcycler instruments |
| Base Color Options | Clear ย |ย White |
| Well Color Options | Clear ย |ย White |
| Plate Labeling | Black print โ all variants |
| Sealing Compatibility | Pressure-sensitive films ย |ย Adhesive seals ย |ย Heat-sealing |
| Footprint | Standard SBS/ANSI 384-well format |
| Sterile | โ ๏ธ Non-Sterile |
| DNase / RNase-free | โ Certified |
| Endotoxin-free | โ Certified |
| Packaging | 10 plates per box ย |ย 100 plates per case |
- Store in original packaging in a clean, dry environment away from direct sunlight and UV exposure
- Maintain storage temperature between 15ยฐC and 30ยฐC prior to use
- Handle plates by the edges โ avoid contaminating well surfaces with skin oils and nucleases
- Use powder-free gloves when handling plates for sensitive nucleic acid applications
- Verify cut corner orientation matches your instrument's plate loading requirements before use
- Use a 384-well compatible multichannel pipette or automated liquid handler for sample loading โ manual pipetting of 384-well plates is not recommended
- Seal plates immediately after sample loading to prevent evaporation of the small 40 ยตL reaction volumes
- Centrifuge briefly at low speed after sealing to collect sample at the well base and remove air bubbles
- Verify plate sits flat in the thermal cycler block โ the rigid PC frame should ensure consistent plate seating
- Dispose of used plates per your institution's biosafety and waste disposal guidelines
Frequently Bought Together