Skip to Content

Low Retention- Pipette Tips in Racks, Universal Fit

🛡️ DNase/RNase · DNA · Pyrogen · ATP-Free
✨ Sterile
  • Low retention surface minimizes sample loss for more accurate pipetting.
  • Ideal for thick, sticky, or viscous liquids and complex reaction mixes.
  • Compatible with most standard pipettes.
  • ⚠️Not autoclavable
  • Compatible with our refillable system.
SKU: PT1-L1000-1 Tip Volume 100-1000µL Clear
  • Select a Tip Volume and Attribute
  • Packaging
Add to wishlist
Price
60.80 60.80 (Tax excluded)

For Research Use Only
Return & Refund Policy
Description
Features
Specifications
Compatibility
Packaging
Storage
FAQs
Related Products
Product Description

Maximize sample recovery and improve accuracy with our low retention pipette tips, compatible with most standard pipettes and engineered for demanding applications.

Designed to prevent liquids from sticking to the inner wall of the tip. Every microliter is delivered — even when working with viscous reagents, proteins, or complex reaction mixes.

Improve accuracy and repeatability across PCR, RT-PCR, DNA sequencing, and other contamination-sensitive workflows. Designed to be compatible with most standard pipettes.

Key Features & Benefits
  • Low retention surface treatment — prevents liquids from adhering to tip walls for maximum sample recovery
  • Ideal for viscous samples — proteins, glycerol-based reagents, enzymes, and complex reaction mixes
  • Precision-molded for a consistent, secure seal with most standard pipettes
  • DNase/RNase, DNA, Pyrogen, and ATP-free — certified safe for sensitive molecular applications
  • Pre-sterilized and sealed to maintain sterility until point of use
  • Available in racked and refill formats — including patented refillable blister-box system
  • Reduces plastic waste — refill system lets you reload only what you need
⚠️ Not autoclavable — heat sterilization will compromise the low retention surface treatment
Specifications
SpecificationDetail
MaterialVirgin polypropylene with low retention surface treatment
FilterNone — standard unfiltered tip
Volume Ranges0.1–10 µL  |  0.1–20 µL  |  1–200 µL  |  1–300 µL  |  100–1000 µL  |  100–1200 µL
SterilityPre-sterilized, sterility maintained in sealed packaging
DNase / RNase-free✓ Certified
DNA-free✓ Certified
Pyrogen-free✓ Certified
ATP-free✓ Certified
Autoclavable⚠️ Not Autoclavable
FormatRacked (ready to use) & Refill (blister-box system)
Tips per Rack96 tips
Compatible BrandsEppendorf, Gilson, Thermo Fisher, Sartorius, BRAND, Dlab, and most standard pipettes
Compatible Pipette Brands

Our low retention pipette tips have been verified compatible with the following brands and models. Always verify fit before use.

  • Eppendorf — Research® Plus (single channel and multichannel, 0.1 µL–1200 µL)
  • Gilson — PIPETMAN® PN and PL Series (single and 8-channel)
  • Thermo Fisher — Finnpipette™ F1, F2, and F3 Series (including µTip models)
  • Sartorius (Biohit) — Proline® Series (single and multichannel)
  • BRAND — Transferpette® Series (single, 8-channel, and 12-channel)
  • Dlab — Single and multichannel models

* For a full model-by-model breakdown, see the Compatibility Chart below on this page.

Packaging & Ordering Information
FormatDetail
Racked96 tips/rack — 10 racks/pkg — pre-loaded, ready to use
Refill96 tips/pack — compatible with patented refillable blister-box system
Racks per Case50 racks (racked format)
PackagingIndividually sealed in sterile packaging
Product CodesSee SKU reference on this page for codes by volume

* Pack sizes vary by volume range. Contact us for bulk pricing or custom orders.

Storage & Handling
  • Store in original sealed packaging in a clean, dry environment away from direct sunlight
  • Maintain storage temperature between 15°C and 30°C (59°F – 86°F)
  • Keep unused tips in a relatively closed space to preserve the sterilization effect
  • Do not use tips from damaged or previously opened packaging
  • Single-use only — do not reuse tips between samples to prevent cross-contamination
⚠️ Not autoclavable — autoclaving will compromise the low retention surface and affect tip performance. Purchase pre-sterilized tips if sterility is required.
Frequently Asked Questions
What does "low retention" mean?
Low retention tips are treated to minimize liquid adhesion to the inner tip wall. This means more of your sample is delivered to the target — reducing waste, improving accuracy, and making a meaningful difference when working with precious or expensive reagents.
When should I use low retention tips instead of standard tips?
Low retention tips are especially valuable when working with viscous samples like glycerol-based reagents, proteins, enzymes, or any liquid that tends to cling to standard tip walls. They are also recommended when sample volume is critical and every microliter counts.
Are these tips compatible with my pipette brand?
Our low retention tips are designed to fit most standard pipette cone sizes and have been tested with Eppendorf, Gilson, Thermo Fisher, Sartorius, BRAND, and Dlab pipettes. See the full compatibility chart on this page for model-specific details.
Can I autoclave these tips?
No. Autoclaving will compromise the low retention surface treatment and affect tip performance. If you require sterile low retention tips, please purchase our pre-sterilized version.
Are these tips certified contaminant-free?
Yes. Our low retention tips are certified DNase/RNase-free, DNA-free, Pyrogen-free, and ATP-free — suitable for PCR, RT-PCR, sequencing, and other sensitive molecular biology applications.
What is the refill system and how does it work?
Our patented refillable blister-box system lets you reload your existing tip rack with a fresh set of 96 tips in one step — no touching, no contamination risk. Simply insert the refill pack into the rack and dispense. You only refill what you need, reducing plastic waste without sacrificing sterility or convenience.
Pipette Compatibility Chart
Low Binding Tips — click a brand to expand model-level compatibility
Compatible
Not Compatible
SC Single Channel
MC-8 8-Channel
MC-12 12-Channel

* Compatibility based on standard cone dimensions. Always verify fit before use. Contact us if your pipette model is not listed.